How to solve the problem of fingerprint access control?

March 21, 2023
First, some users' fingerprint access control often cannot be verified and passed. How to solve this problem?

Some of the following situations may make it difficult for some employees to use or not use fingerprints for access control:

Fingerprints on some fingers are flattened;
2 There are too many folds on the fingers and often change;
3 Severe peeling on the fingers;

Users with unrecognized fingerprints can delete the fingerprint and register it again, or register another finger.

When registering fingerprints, such users need to choose to use better-quality fingerprints (less creases, lack of skin, and clear fingerprints), try to make the fingers contact the fingerprint collector with a larger area, and perform comparison tests after the registration is completed; and Register a few more backup fingers.

In addition, our access control system provides a 1:1 comparison method and password function. You can set these employees to use the 1:1 method and password for access control management.

Second, when access control machines cannot communicate, what are the reasons?

The possible causes are as follows: 1 The communication port is not set correctly, and the selected communication port is not the actual COM port. 2 The baud rate of the computer's communication port is different from the baud rate setting of the attendance machine. 3 The access controller was not connected to the power supply or connected to the computer; 4 The access control was connected but not turned on. 5 The connected terminal number is incorrect. 6 Data lines or converters cannot communicate. 7 The computer's COM port is broken.

Third, after the access control machine is powered on, the liquid crystal display is incomplete, sometimes only shows half, and sometimes the screen is displayed. What is the problem? How to solve it?

The possible reason is 1 bad motherboard; 2 LCD's internal characteristics problems. In this case, contact the supplier and return to service.

Fourth, how to clear the administrator of the access control?

You can use the door access computer and computer communication. After successful communication, enter the access control management tab page. Click the Clear administrator button to clear the administrator of the access control machine. After disconnecting, you can enter the access control menu mode.

5. What is the reason why the sound of the flute sounds when the access control communication is connected?

1 If the above phenomenon occurs when using RS-232 communication, the baud rate of the computer and the baud rate setting of the time attendance are inconsistent.

2 If RS-485 communication is used, it may be that the two lines of the converter's communication line are reversed, or the two lines are stuck together.

6. After the access control machine is turned on, it has repeatedly displayed "please press (leave) fingers". What is the problem and how should it be solved?

The reason for this problem may be:

1 The use of a long time, the collector head surface becomes dirty, or scratches, make the collector head mistakenly believe that the surface is pressed by the finger, and can not pass, so this problem occurs. In this case, adhesive tape can be used to paste the dirt on the surface of the collecting head.
2 The connection of the fingerprint acquisition head is loosened or loosened.
3 motherboard chip is broken.
If the second and third items are two reasons, you need to contact the supplier to apply for warranty.

7. When operating in the access control management, there is no problem in downloading the fingerprint and password data, but when reading the access control record, it prompts failure or midway error. How to solve it?

This situation may be related to the data line, or the converter, or the COM port of the computer. At this time, you can reduce the baud rate of the access control machine and the computer. If it is set to 19200 or 9600, read it again.
Hubungi Kami

Author:

Ms. Yanjun Chen

Phone/WhatsApp:

+8613602572892

Produk popular
You may also like
Related Categories

E-mel kepada pembekal ini

Subjek:
E-mel:
Mesej:

Your message must be betwwen 20-8000 characters

Rumah

Product

Phone

Tentang kita

Siasatan

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Menghantar